{"id":11896,"date":"2026-08-18T09:24:00","date_gmt":"2026-08-18T09:24:00","guid":{"rendered":"https:\/\/mbmlog.com\/?p=11896"},"modified":"2026-08-18T09:24:00","modified_gmt":"2026-08-18T09:24:00","slug":"how-many-electric-forklifts-fit-40hq-container-in","status":"publish","type":"post","link":"https:\/\/mbmlog.com\/fr\/how-many-electric-forklifts-fit-40hq-container-in\/","title":{"rendered":"How Many Electric Forklifts Fit in a 40HQ Container?"},"content":{"rendered":"<style>article img, .entry-content img, .post-content img, .wp-block-image img, figure img, p img {max-width:100% !important; height:auto !important;}figure { max-width:100%; }img.top-image-square {width:280px !important; height:280px !important; object-fit:cover !important;border-radius:12px; box-shadow:0 2px 12px rgba(0,0,0,0.10);}@media (max-width:600px) {img.top-image-square { width:100% !important; height:auto !important; max-height:300px; }p:has(> img.top-image-square) { float:none !important; margin:0 auto 15px auto !important; text-align:center; }}.claim { background-color:#fff4f4; border-left:4px solid #e63946; border-radius:10px; padding:20px 24px; margin:24px 0; font-family:system-ui,sans-serif; line-height:1.6; position:relative; box-shadow:0 2px 6px rgba(0,0,0,0.03); }.claim-true { background-color:#eafaf0; border-left-color:#2ecc71; }.claim-icon { display:inline-block; font-size:18px; color:#e63946; margin-right:10px; vertical-align:middle; }.claim-true .claim-icon { color:#2ecc71; }.claim-title { display:flex; align-items:center; font-weight:600; font-size:16px; color:#222; }.claim-label { margin-left:auto; font-size:12px; background-color:#e63946; color:#fff; padding:3px 10px; border-radius:12px; font-weight:bold; }.claim-true .claim-label { background-color:#2ecc71; }.claim-explanation { margin-top:8px; color:#555; font-size:15px; }.claim-pair { margin:32px 0; }<\/style>\n<p style=\"float: right; margin-left: 15px; margin-bottom: 15px;\">\n  <img decoding=\"async\" style=\"max-width:100%;\" src=\"https:\/\/mbmlog.com\/wp-content\/uploads\/2026\/08\/v2-article-1786527652811-1.jpg\" alt=\"Electric forklifts loaded and arranged inside a 40HQ shipping container (ID#1)\" class=\"top-image-square\">\n<\/p>\n<p>Guessing how many electric forklifts fit in a 40HQ container can wreck your landed cost. One wasted container slot means thousands of dollars lost. Our loading team in Zhengzhou solves this puzzle every week for [importers](https:\/\/mbmlog.com\/?p=11621).<\/p>\n<p><strong>A 40HQ container typically fits 3 to 4 fully assembled 2.0\u20132.5 ton electric forklifts, or 6 to 7 units when shipped Semi-Knocked Down (SKD). Compact electric pallet trucks can reach 15\u201325 units, while large 3-ton reach trucks may fit only 2 per container.<\/strong><\/p>\n<p>The exact number depends on your forklift model, mast height, and loading method. Below, I break down each factor so you can plan your shipment with confidence.<\/p>\n<h2>How many electric forklifts can I fit in a 40HQ container without damaging them during transit?<\/h2>\n<p>Last year, a US dealer sent us photos of forklifts that arrived scratched and shifted after using a cheap forwarder. Our <a href=\"https:\/\/mbmlog.com\/?p=11535\">container loading plans<\/a> are designed to prevent exactly that outcome.<\/p>\n<p><strong>Without risking transit damage, a 40HQ container safely holds 3\u20134 assembled 2.0\u20132.5 ton electric counterbalance forklifts, or 6\u20137 SKD units with masts detached. Each unit must be lashed to floor rings with heavy-duty straps and secured with timber blocking and bracing.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/mbmlog.com\/wp-content\/uploads\/2026\/08\/v2-article-1786527657520-2.jpg\" alt=\"Electric counterbalance forklifts secured with straps and blocking inside 40HQ container (ID#2)\" title=\"Forklift Loading Capacity\"><\/p>\n<p>The number of forklifts you can load and the number you can load safely are two different things. I have seen suppliers squeeze extra units into a container by skipping proper securing. That gamble rarely pays off. During a Pacific crossing, a container can pitch and roll for weeks. An unsecured 3,000 kg forklift becomes a battering ram.<\/p>\n<h3>Realistic capacity by forklift type<\/h3>\n<p>Here is what we typically achieve in a 40HQ when cargo safety comes first:<\/p>\n<table>\n<thead>\n<tr>\n<th>Equipment Type<\/th>\n<th>Assembled<\/th>\n<th>SKD \/ Disassembled Shipping<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2.0\u20132.5 ton electric counterbalance forklift<\/td>\n<td>3\u20134 units<\/td>\n<td>6\u20137 units<\/td>\n<\/tr>\n<tr>\n<td>Compact electric pallet trucks<\/td>\n<td>15\u201325 units<\/td>\n<td>25+ units<\/td>\n<\/tr>\n<tr>\n<td>Electric stackers<\/td>\n<td>8\u201312 units<\/td>\n<td>12\u201316 units<\/td>\n<\/tr>\n<tr>\n<td>3-ton reach \/ multi-directional trucks<\/td>\n<td>2 units<\/td>\n<td>3\u20134 units<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>What &quot;damage-free&quot; loading requires<\/h3>\n<p>Lashing and securing are not optional extras. Every forklift we load gets strapped to the container&#39;s floor lashing rings. Timber blocking and bracing goes between units and against the container walls to stop any forward or lateral shift. Wheels are chocked. Forks are lowered flat or removed.<\/p>\n<p>There is one more risk many buyers overlook: humidity. Sea transit exposes electronics to weeks of moist salt air. We recommend <a href=\"https:\/\/en.wikipedia.org\/wiki\/Volatile_corrosion_inhibitor\" target=\"_blank\" rel=\"noopener noreferrer\">Vapor Corrosion Inhibitor<\/a> <sup id=\"ref-1\"><a href=\"#footnote-1\" class=\"footnote-ref\">1<\/a><\/sup> (VCI) shrink-wrapping over the PCB controllers and battery terminals. Without it, a forklift can arrive looking perfect but fail to power on. Repairing corroded electronics at destination costs far more than the wrapping does.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> SKD packing can nearly double the number of forklifts per 40HQ container <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">Removing masts, overhead guards, and wheels reduces each unit's height and footprint, raising capacity from 3\u20134 assembled units to 6\u20137 units per 40HQ.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim claim-true\"><\/div>\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> Forklifts are heavy enough to stay in place without lashing during ocean transit <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">Ocean swells generate forces that can slide even a 3-ton machine across the container floor; unsecured forklifts routinely arrive with crushed panels, bent masts, and damaged battery casings.<\/div>\n<\/div>\n<\/div>\n<h2>What factors affect how many electric forklifts I can load into a 40HQ container?<\/h2>\n<p>Whenever a buyer asks me for a freight quote, my first three questions are always the same: What are the shipping dimensions? What is the mast height? Assembled or SKD?<\/p>\n<p><strong>Five factors determine 40HQ capacity: overall shipping dimensions, collapsed mast height versus the 2.58m door opening, chassis width versus the 2.35m internal width, total weight against the 28.6-ton payload, and whether the supplier ships units assembled or Semi-Knocked Down.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/mbmlog.com\/wp-content\/uploads\/2026\/08\/v2-article-1786527660260-3.jpg\" alt=\"Key factors like mast height and chassis width affecting 40HQ forklift loading capacity (ID#3)\" title=\"Factors Affecting Capacity\"><\/p>\n<p>Most buyers assume weight is the limit. In practice, it almost never is. A 40HQ offers roughly 28.6 tons of payload capacity, but forklifts &quot;cube out&quot; the container long before they &quot;weigh out&quot; it. Four assembled 2.5-ton electric forklifts weigh around 16 tons combined. You run out of usable floor space first.<\/p>\n<h3>The door opening is the real gatekeeper<\/h3>\n<p>The 40HQ <a href=\"https:\/\/en.wikipedia.org\/wiki\/Intermodal_container#Specifications\" target=\"_blank\" rel=\"noopener noreferrer\">door opening<\/a> <sup id=\"ref-2\"><a href=\"#footnote-2\" class=\"footnote-ref\">2<\/a><\/sup> height is approximately 2.58 meters. Any forklift with a collapsed mast height above that simply cannot roll in. Many standard duplex masts collapse to around 2.0\u20132.2 meters, which works. Triplex masts and full free-lift masts often exceed the limit. In those cases, we arrange for the mast to be detached and shipped alongside the chassis.<\/p>\n<h3>Width kills side-by-side loading<\/h3>\n<p>The <a href=\"https:\/\/www.hapag-lloyd.com\/en\/products\/containers.html\" target=\"_blank\" rel=\"noopener noreferrer\">internal width<\/a> <sup id=\"ref-3\"><a href=\"#footnote-3\" class=\"footnote-ref\">3<\/a><\/sup> of a 40HQ is about 2.35 meters. A typical 2-ton electric forklift chassis measures 1.1\u20131.2 meters wide. Two units side by side need 2.2\u20132.4 meters plus clearance for blocking and bracing. It does not fit. So forklifts load in a single line, which is why floor length becomes the binding constraint.<\/p>\n<h3>Smart placement recovers space<\/h3>\n<p>There is a technique we use often: interlocking placement. By alternating the direction of every other forklift and removing the forks, the counterweight of one unit nests beside the mast area of the next. This can recover up to 15% of wasted floor space \u2014 sometimes enough to fit one additional unit.<\/p>\n<table>\n<thead>\n<tr>\n<th>Constraint<\/th>\n<th>40HQ Specification<\/th>\n<th>Typical 2-ton Electric Forklift<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Door opening height<\/td>\n<td>~2.58 m<\/td>\n<td>Collapsed mast: 2.0\u20132.2 m (duplex)<\/td>\n<\/tr>\n<tr>\n<td>Internal width<\/td>\n<td>~2.35 m<\/td>\n<td>Chassis width: 1.1\u20131.2 m<\/td>\n<\/tr>\n<tr>\n<td>Payload capacity<\/td>\n<td>~28.6 tons<\/td>\n<td>~3.0\u20134.0 tons per unit<\/td>\n<\/tr>\n<tr>\n<td>Internal length<\/td>\n<td>~12.03 m<\/td>\n<td>Length with forks: 3.0\u20133.5 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> A 40HQ container cubes out before it weighs out when loading electric forklifts <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">Four assembled forklifts use nearly all usable floor length while consuming barely half of the container's 28.6-ton payload capacity.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> Two standard 2-ton forklifts can be loaded side by side in a 40HQ <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">With chassis widths of 1.1\u20131.2 m each, two units need more than the 2.35 m internal width once securing clearance is added, so single-file loading is standard.<\/div>\n<\/div>\n<\/div>\n<h2>Should I choose a 40HQ or 40FT container for shipping multiple electric forklifts from China?<\/h2>\n<p>One trade-off comes up in almost every booking we handle: the 40HQ often costs nearly the same as a standard 40FT, yet gives you roughly 30 cm of extra height.<\/p>\n<p><strong>Choose a 40HQ for shipping electric forklifts. It offers about 2.69m internal height versus 2.39m in a standard 40FT, at nearly identical ocean freight costs. The extra 30cm allows taller collapsed masts to enter assembled, avoiding disassembly labor and reassembly risk.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/mbmlog.com\/wp-content\/uploads\/2026\/08\/v2-article-1786527662868-4.jpg\" alt=\"Comparison of 40HQ versus 40FT container height for shipping assembled electric forklifts (ID#4)\" title=\"40HQ vs 40FT Container\"><\/p>\n<p>For a quick decision, here is how the two containers compare for material handling equipment:<\/p>\n<table>\n<thead>\n<tr>\n<th>Feature<\/th>\n<th>40FT (40GP)<\/th>\n<th>40HQ (High Cube)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Internal height<\/td>\n<td>~2.39 m<\/td>\n<td>~2.69 m<\/td>\n<\/tr>\n<tr>\n<td>Door opening height<\/td>\n<td>~2.28 m<\/td>\n<td>~2.58 m<\/td>\n<\/tr>\n<tr>\n<td>Internal length<\/td>\n<td>~12.03 m<\/td>\n<td>~12.03 m<\/td>\n<\/tr>\n<tr>\n<td>Internal width<\/td>\n<td>~2.35 m<\/td>\n<td>~2.35 m<\/td>\n<\/tr>\n<tr>\n<td>Payload capacity<\/td>\n<td>~28.7 tons<\/td>\n<td>~28.6 tons<\/td>\n<\/tr>\n<tr>\n<td>Best for<\/td>\n<td>Low-profile pallet trucks, stackers<\/td>\n<td>Counterbalance forklifts with masts<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Notice that the floor dimensions are identical. The 40HQ does not let you load more forklifts across or along the floor. What it changes is which forklifts can enter at all.<\/p>\n<h3>Why the door opening decides it<\/h3>\n<p>A standard 40FT has a door opening of roughly 2.28 meters. Many electric counterbalance forklifts have collapsed mast heights of 2.1\u20132.3 meters. That leaves almost no clearance in a 40GP \u2014 sometimes none at all. The 40HQ door opening of about 2.58 meters gives comfortable clearance for most duplex masts, plus room for ramp angles during driving or towing the unit inside.<\/p>\n<h3>When the 40FT still makes sense<\/h3>\n<p>If your entire order is low-profile equipment \u2014 electric pallet trucks, walkie stackers, or SKD chassis with masts removed \u2014 a 40GP works fine. In some port pairs during tight seasons, 40GP availability is better, and the rate can be slightly lower. But for mixed loads or assembled counterbalance units, I book the 40HQ almost every time. The small rate difference is cheap insurance against a forklift stuck at the container door on loading day. In our experience shipping from Chinese factories to the US, the reassembly labor saved at destination alone justifies the high cube.<\/p>\n<h2>Can I ship forklift batteries and chargers together with my forklifts in the same 40HQ container?<\/h2>\n<p>A distributor once asked us to consolidate forklifts from one factory, lithium batteries from a second, and chargers from a third \u2014 into one container. We do this kind of multi-supplier consolidation regularly.<\/p>\n<p><strong>Yes, forklift batteries and chargers can ship in the same 40HQ container as the forklifts. Lithium batteries require UN38.3 test documentation and Class 9 dangerous goods declaration, while chargers and lead-acid batteries in sealed condition face simpler requirements. Proper crating and securing are mandatory.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/mbmlog.com\/wp-content\/uploads\/2026\/08\/v2-article-1786527665592-5.jpg\" alt=\"Forklift batteries and chargers packed safely alongside forklifts in 40HQ container (ID#5)\" title=\"Shipping Batteries and Chargers\"><\/p>\n<p>Batteries are where inexperienced forwarders get importers into trouble. The rules differ by battery chemistry and by whether the battery ships installed or separately, so let me walk through the practical picture we manage for clients every month.<\/p>\n<h3>Lithium versus lead-acid: what changes<\/h3>\n<p>Lithium-ion batteries installed in equipment, or shipped separately, generally fall under <a href=\"https:\/\/www.phmsa.dot.gov\/training\/hazmat\/shipping-lithium-batteries-guide\" target=\"_blank\" rel=\"noopener noreferrer\">Class 9 dangerous goods<\/a> <sup id=\"ref-4\"><a href=\"#footnote-4\" class=\"footnote-ref\">4<\/a><\/sup> for ocean freight. That means the carrier needs proper declaration, UN38.3 test summaries, and compliant packaging before booking is accepted. Miss a document and the container sits at the port while storage charges climb.<\/p>\n<p>There is a useful side benefit to lithium, though. Lithium-ion models are often 15\u201320% lighter than lead-acid versions. That reduces total container weight and lowers the risk of exceeding axle load limits \u2014 roughly 12,000 lbs per wheel matters when the loaded container travels by truck at destination.<\/p>\n<h3>Separate battery crates can simplify things<\/h3>\n<p>One strategy we sometimes recommend: ship the batteries in separate, specialized crates rather than installed. This can simplify the hazardous materials documentation for the forklift chassis itself, and it allows more flexible positioning of the non-hazardous components inside the container. Chargers, forks, spare parts, and attachments then fill the gaps above and between chassis units \u2014 palletized, strapped, and braced so nothing rests against battery casings.<\/p>\n<h3>A quick pre-booking checklist<\/h3>\n<ol>\n<li>Confirm battery chemistry and whether it ships installed or crated separately.<\/li>\n<li>Request UN38.3 reports and MSDS from the battery supplier before booking.<\/li>\n<li>Verify the carrier accepts Class 9 cargo on your route.<\/li>\n<li>Plan the container loading plan so heavy batteries sit low and centered for weight distribution.<\/li>\n<li>Use spare parts and chargers as void fillers \u2014 but crate and lash them independently.<\/li>\n<\/ol>\n<p>Done right, consolidation cuts your ocean freight costs per unit significantly. Done wrong, it triggers port holds. The difference is preparation before the cargo ever reaches the terminal.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> Lithium forklift batteries require Class 9 dangerous goods documentation for ocean shipping <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">Lithium-ion batteries are classified as Class 9 hazardous materials, and carriers require UN38.3 test summaries and proper declaration before accepting the booking.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> Batteries and chargers must always ship in a separate container from the forklifts <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">With correct documentation, crating, and securing, batteries and chargers can legally and safely share the same 40HQ container as the forklifts, which lowers per-unit shipping cost.<\/div>\n<\/div>\n<\/div>\n<h2>Conclusion<\/h2>\n<p>A 40HQ fits 3\u20134 assembled electric forklifts or 6\u20137 SKD units. Verify mast height, dimensions, and battery documents early \u2014 then loading, securing, and consolidation protect your landed cost.<\/p>\n<h2>Footnotes<\/h2>\n<p><span id=\"footnote-1\"><br \/>\n1. Technical explanation of VCI technology used to protect electronics from salt air during transit. <a href=\"#ref-1\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-2\"><br \/>\n2. Authoritative source providing standardized ISO dimensions for 40HQ container door openings. <a href=\"#ref-2\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-3\"><br \/>\n3. Authoritative container specifications from a global carrier to verify 40HQ internal dimensions. <a href=\"#ref-3\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><span id=\"footnote-4\"><br \/>\n4. Official government guidance on shipping lithium batteries as hazardous materials for ocean transport. <a href=\"#ref-4\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How Many Electric Forklifts Fit in a 40HQ Container?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A 40HQ container typically fits 3 to 4 fully assembled 2.0\u20132.5 ton electric forklifts, or 6 to 7 units when shipped Semi-Knocked Down (SKD). Compact electric pallet trucks can reach 15\u201325 units, while large 3-ton reach trucks may fit only 2 per container.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How many electric forklifts can I fit in a 40HQ container without damaging them during transit?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Without risking transit damage, a 40HQ container safely holds 3\u20134 assembled 2.0\u20132.5 ton electric counterbalance forklifts, or 6\u20137 SKD units with masts detached. Each unit must be lashed to floor rings with heavy-duty straps and secured with timber blocking and bracing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What factors affect how many electric forklifts I can load into a 40HQ container?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Five factors determine 40HQ capacity: overall shipping dimensions, collapsed mast height versus the 2.58m door opening, chassis width versus the 2.35m internal width, total weight against the 28.6-ton payload, and whether the supplier ships units assembled or Semi-Knocked Down.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Should I choose a 40HQ or 40FT container for shipping multiple electric forklifts from China?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Choose a 40HQ for shipping electric forklifts. It offers about 2.69m internal height versus 2.39m in a standard 40FT, at nearly identical ocean freight costs. The extra 30cm allows taller collapsed masts to enter assembled, avoiding disassembly labor and reassembly risk.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I ship forklift batteries and chargers together with my forklifts in the same 40HQ container?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, forklift batteries and chargers can ship in the same 40HQ container as the forklifts. Lithium batteries require UN38.3 test documentation and Class 9 dangerous goods declaration, while chargers and lead-acid batteries in sealed condition face simpler requirements. Proper crating and securing are mandatory.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n<p><script type=\"application\/ld+json\">\n[\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"SKD packing can nearly double the number of forklifts per 40HQ container\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Forklifts are heavy enough to stay in place without lashing during ocean transit\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"A 40HQ container cubes out before it weighs out when loading electric forklifts\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Two standard 2-ton forklifts can be loaded side by side in a 40HQ\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Lithium forklift batteries require Class 9 dangerous goods documentation for ocean shipping\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Batteries and chargers must always ship in a separate container from the forklifts\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  }\n]\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A 40HQ container fits 3-4 assembled electric forklifts or 6-7 SKD units; learn proper lashing, blocking, and VCI protection to avoid transit damage.<\/p>","protected":false},"author":2,"featured_media":11891,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[48],"tags":[],"class_list":["post-11896","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-import-electrical-forklift-from-china"],"_links":{"self":[{"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/posts\/11896","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/comments?post=11896"}],"version-history":[{"count":1,"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/posts\/11896\/revisions"}],"predecessor-version":[{"id":12757,"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/posts\/11896\/revisions\/12757"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/media\/11891"}],"wp:attachment":[{"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/media?parent=11896"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/categories?post=11896"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mbmlog.com\/fr\/wp-json\/wp\/v2\/tags?post=11896"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}